Analysis of Corticosteroids in Cosmetics by Reversed Microemulsion Electrokinetic Chromatography with 1 Butyl 3 methylimizolium Tetrafluoborate Ionic Liquid as Additive |
|
View Full Text Download reader |
DOI:10.3969/j.issn.1004-4957.年份.月份 |
KeyWord:microemulsion electrokinetic chromatography corticosteroids ionic liquid cosmetics |
Author | Institution |
CHEN Xin1,TIAN Zhizhuang2,LIU Ying1,HUANG Yao1,CAO Yuhua1 |
1.江南大学化学与材料工程学院;2.郑州轻工业学院材料与化学工程学院 |
|
Hits: 1979 |
Download times: 921 |
Abstract: |
A reversed microemulsion electrokinetic chromatographic(MEEKC) method was developed for the separation of three corticosteroids,including hydrocortisone,prednisone and hydrocortisone acetate by using 1 butyl 3 methylimizolium tetrafluoborate(BMIM-BF4) ionic liquid(IL) as additive.The effects of experimental conditions such as BMIM-BF4 concentration and pH value on separation efficiency were investigated.The optimized conditions were as follows:24% sodium dodecyl sulfate(SDS),66% 1 butanol,05% n octane,35 mmol/L BMIM-BF4,pH 22 20 mmol/L NaH2PO4,an applied voltage of -20 kV and a detection wavelength of 250 nm.Under the optimized conditions,the calibration curves were linear in the range of 5-400,5-400,5-800 mg?L-1 for hydrocortisone,prednisone and hydrocortisone acetate with detection limits(S/N=3) of 09,09,12 mg/L,respectively.The RSDs(n=3) were less than 43%.The average spiked recoveries were 102%,97% and 94%,respectively.The results showed that the resolution of the IL-MEEKC method for the separation of hydrocortisone,prednisone and hydrocortisone acetate was higher than that of the conventional MEEKC method.The proposed method was simple,rapid and effective,and could be used for the quality control of cosmetics. |