Determination of Salicylic Acid by High Performance Liquid Chromatography with Ionic Liquids as Mobile Phase Additives
  
View Full Text    Download reader
DOI:10.3969/j.issn.1004-4957.年份.月份
KeyWord:ionic liquid  high performance liquid chromatography  salicylic acid  ultraviolet detection  pharmaceutical
  
AuthorInstitution
董影杰,于泓,黄旭,王婧菲 哈尔滨师范大学化学化工学院
Hits: 2948
Download times: 1225
Abstract:
      A reverse phase high performance liquid chromatographic method was established for the determination of salicylic acid by using ionic liquids as mobile phase additives.The chromatographic separation of salicylic acid was performed on a ZORBAX ODS column(250 mm×4.6 mm id,5 μm).The detection of salicylic acid was carried out by ultraviolet(UV) detection.The effects of detection wavelength,pH value,concentration and alkyl chain length of ionic liquids on the separation and determination of salicylic acid were investigated.The optimum chromatographic conditions were as follows:mobile phase:methanol-30 mmol?L-1 1 butyl 3 methylimidazolium tetrafluoroborate aqueous solution(pH 3.0,adjusted with acetic acid) (60∶40,by volume),UV detection wavelength:300 nm,flow rate:10 mL?min-1,column temperature:30 ℃.Under the optimal conditions,the retention time of salicylic acid was about 4.4 min.The calibration curve showed a good linearity over the range of 2-100 mg?L-1 for salicylic acid with a correlation coefficient of 0.999 9.The detection limit was 0.059 mg/L.The average spiked recovery was 100% with relative standard deviation of 0.11%.The method was successfully applied in the determination of the content of salicylic acid in the pharmaceutical of Zujunqing Tinctura.
Close