Determination of Celastrol by Lanthanide Sensitized Fluorescence Quenching on Terbium- Enoxacin-SDS
  
View Full Text    Download reader
DOI:10.3969/j.issn.1004-4957.年份.月份
KeyWord:celastrol  terbium  enoxacin  SDS  fluorescence quenching
  
AuthorInstitution
吕菊波 鲁东大学化学与材料科学学院
Hits: 2992
Download times: 1464
Abstract:
      In NH3-NH4Cl buffer solution(pH 9.3),terbium(Ⅲ) reacted with enoxacin (ENX) to form fluorescence coordinate compound with the maximum excitation wavelength of 330 nm and the maximum emission wavelength of 545 nm.The presence of SDS obviously strengthened the fluorescence intensity,but the fluorescence intensity of the complex was diminished by continuously adding celastrol,while the locations of the excitation and emission wavelengths were kept the same.Based on this,a new fluorescence method was proposed for the determination of celastrol.The method is simple,rapid and sensitive.The linear range of celastrol is 5.2×10-6-8.4×10-5 mol/L and the detection limit is 4.1×10-8 mol/L.
Close