Determination of 2,3-Butanediol Isomers in Irradiated Liquor Using Chiral Capillary Column with Gas Chromatography
  
View Full Text    Download reader
DOI:10.3969/j.issn.1004-4957.年份.月份
KeyWord:2,3-butanediol  isomers  wine  gas chromatography  irradiation
  
AuthorInstitution
余书奇,奚星林,陈文锐,晏日安,邵仕萍,潘丙珍,庞世琦 1.暨南大学理工学院;2.广东出入境检验检疫局检验检疫技术中心
Hits: 2448
Download times: 1315
Abstract:
      A chiral capillary column with gas chromatographic method was developed for the determination of three isomers of 2,3-butanediol,e.g.(2S,3S)-(+)-butanediol(d-BT for short),(2R,3R)-(-)-butanediol(l-BT for short)and meso-(R,S)-butanediol(meso-BT for short),in liquor sample.The samples were extracted via vibration with ethyl acetate and methanol(4∶1) mixed solution.The extract was purified with graphitization carbon black column using solid phase extraction device.The 2,3-butanediol isomers were separated on a CP-Chirasil-DEX CB capillary column,and detected with flame ionization detector.The quantification of three isomers was performed by the external standard method.The calibration curves of d-BT,l-BT and meso-BT were linear in the ranges of 10-75,60-300,20-100 mg/L,respectively,with correlation coefficients of 0.999 1,0.999 6 and 0.999 9,respectively.The spiked recoveries of three butanediol isomers were 90%-113% in wine with RSDs(n=6)of 1.1%-7.2%,and 96%-99% in spirit with RSDs(n=6)of 1.7%-3.8%,respectively.The detection limit was 1.0 mg/L.The method was applied in the determinations of d-BT,l-BT and meso-BT in wine samples and sipirit samples before and after irradiated by Cobalt 60-gamma rays with irradiation dose of 10 kGy.The results showed that d-BT was detected in spirit samples after irradiation,but no obvious change of d-BT content occured in red wine,which could provide an evidence on whether the sipirit samples were irradiated or not.
Close