Determination of Iodate and Bromate in Cosmetics by Ion Chromatography with Postcolumn Deriviation and UV Detection
  
View Full Text    Download reader
DOI:10.3969/j.issn.1004-4957.年份.月份
KeyWord:ion chromatography  post-column derivatization  cosmetics  iodate  bromate
  
AuthorInstitution
王红青,肖海龙,阮小娇,王娜,黄建萍,王啸 杭州市质量技术监督检测院
Hits: 3358
Download times: 1406
Abstract:
      An ion chromatographic method with post-column deriviation and UV detection for the determination of iodate and bromate in cosmetics was developed and validated.The sample was purified with a guard-column IonPac AG11-HC(50 mm×4 mm),and separated on an analytical column IonPac AS11-HC(250 mm×4 mm) using KOH as an eluent with a self-regeneration suppressor.NaNO2 and KBr were used as the post-column deriviation solution.The analyte was quantitatively analysed by external standard and detected with a DAD detector.The results showed that the calibration curves were linear in the range of 2.0-1 000 mg/kg with correlation coefficients not less than 0.999 8.The spiked recoveries were in the range of 84%-99% with relative standard deviations(RSDs,n=3) less than 2%.With advantages of simplicity,good reproducibility and high sensitivity,the method was suitable for the determination of iodate and bromate in cosmetics.