Determination of Main Sulfur-contained Compounds in Cooked Oil by Headspace Gas Chromatographic Method |
|
View Full Text Download reader |
DOI:10.3969/j.issn.1004-4957.年份.月份 |
KeyWord:garlic sulfur-contained compound determination headspace gas chromatography |
Author | Institution |
李文清,周美云,彭楚婷,晏日安,周华 |
1.暨南大学理工学院食品科学与工程系; 2.暨南大学生命科学与技术学院化学系 |
|
Hits: 2648 |
Download times: 1111 |
Abstract: |
In order to analyze the change of concentration of main sulfur-contained compounds in different cooking ways,a headspace gas chromatographic method was established and validated for the determination of diallyl sulfide(DAS ),diallyl disulfide(DADS),diallyl trisulfide(DATS) in cooked oil.The detection was performed on a DM2WAX capillary column,with an equilibration temperature of 403 K,an equilibration time of 20 min and a rotation rate of 500 r/min.Good linear relationships between peak area and their contents were obtained in the investigated range,with correlation coefficients higher than 0.999 and detection limits of 0.001-0.025 mg/L.The average recoveries of DAS,DADS and DATS were in the range of 97.1%-103%. |