Determination of Amantadine Residues in Pepper and Pepper Products by High Performance Liquid Chromatography Coupled with Tandem Mass Spectrometry
  
View Full Text    Download reader
DOI:10.3969/j.issn.1004-4957.年份.月份
KeyWord:high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)  amantadine  pepper  pepper products
  
AuthorInstitution
HU Qiao-ru,ZHOU Chang-peng,ZHANG Yu-chun,CUI Jia,JU Ling-yan,YANG Li-jun 威海出入境检验检疫局检验检疫技术中心
Hits: 2968
Download times: 1141
Abstract:
      A high performance liquid chromatography tandem mass spectrometric(HPLC-MS/MS) method was developed for the determination of amantadine residues in pepper and pepper products.After extracted with 1% trichloroacetic acid solution-methanol(1∶1) and purified by an Oasis-MCX SPE cartridge,the samples were sepatated on an Atlantis T3 C18 column(3.0 μm,2.1 mm× 150 mm)by gradient elution.The electrospray was operated in positive mode and the samples were monitored under the multiple reaction monitoring(MRM) mode.The calibration curves showed good linearity in the range of 1.0-50 μg/kg.The quantitation limit was 1.0 μg/kg for fresh pepper,and 5.0 μg/kg for dried pepper and chili products.The recoveries of amantadine in fresh pepper at spiked levels of 1.0,2.0,5.0 μg/kg were 72.2%-98.2%,with relative standard deviations(RSDs,n=6) of 1.2%-4.6%,and recoveries in dry pepper and chili products at spiked levels at 5.0,10.0,25.0 μg/kg were 64.2%-81.6%,with RSDs(n=6) of 1.3%-6.3%.With advantages of simple operation,high sensitivity,good reproducibility,the method could be used for the detection of amantadine residues in the pepper and pepper products.
Close