Determination of Histamine in Fish Samples Based on Colloidal Gold Modified Electrode |
|
View Full Text Download reader |
DOI: |
KeyWord:histamine colloidal gold current-time curve method fish samples |
Author | Institution |
ZHOU Chan-yuan,ZHAO Xiao-juan,WANG Chun-li,ZENG Xiao-fang,BAI Wei-dong |
1.College of Light Industry and Food Science,Zhongkai University of Agriculture and Engineering;2.Jiangmen Customs District Peoples Republic of China |
|
Hits: 2313 |
Download times: 1118 |
Abstract: |
A simple and sensitive method was established for the detection of histamine by using the current-time curve based on a colloidal gold modified glass carbon electrode(AuCS/GCE).The electrochemical properties of the modified electrode were investigated.The pH value of the base solution,and the electrochemical detection methods and conditions for histamine were optimized.Results showed that there was a good linear relationship for the response current(-I,μA) of histamine on the AuCS/GCE in the concentration(c,μmol/L) range of 0.1-64 μmol/L,with the detection limit of 0.033 μmol/L.The recoveries for histamine in the hairtail and yellow croaker samples were in the ranges of 94.4%-106% and 91.8%-106%,respectively.The method was simple,rapid and low cost,and was suitable for the determination of histamine in food samples such as hairtail and yellow croaker. |
Close |
|
|
|