Simultaneous Determination of Heavy Metal Elements in E-cigarette Aerosols by Inductively Coupled Plasma Mass Spectrometry |
|
View Full Text Download reader |
DOI: |
KeyWord:e-cigarette aerosols heavy metals Au nitric solution inductively coupled plasma mass spectrometry(ICP-MS) |
Author | Institution |
LU Yi-feng,LI Yong-xia,ZHANG Hui-zi,LIU Hong,YAO He-ming,ZHENG Sai-jing,CHEN Yong |
1.Technology Center,Shanghai Tobacco Group Co.,Ltd.;2.Shanghai Peony Flavors and Fragrances Co.,Ltd. |
|
Hits: 1943 |
Download times: 802 |
Abstract: |
A method of inductively coupled plasma mass spectrometry(ICP-MS) with Au solvent trapping was established for the simultaneous determination of 7 kinds of heavy metal elements,i.e.chromium,nickel,arsenic,lead,cadmium,antimony and mercury in e-cigarette aerosols.The trapping conditions for e-cigarette aerosols were optimized.The aerosols were trapped with dilute nitric acid solution(5.0%,by volume) containing 2.0 mg/L Au solution.Two impingers were tandemly connected,in which each contained 25.0 mL trapping solution,and the puffing number was 100.Results showed that,seven elements in e cigarette aerosols were trapped effectively.Under the optimal conditions,the calibration curves were linear in the range of 0.3-80 μg/L for Cr,Ni, As,Pb,Cd,and 0.3-10 μg/L for Sb,Hg,with their correlation coefficients(r2) larger than 0.999.The limits of detection(LODs) for seven elements were in the range of 0.69-1.19 ng/100 puffs,and the limits of quantitation were 2.29-3.97 ng/100 puffs.The recoveries ranged from 96.5% to 103% with relative standard deviations(RSD) of 6.6%-14%10 commercial e-cigarettes were determined by this method and the French Standardization,respectively,and the detection results were consistent.Therefore,this method was accurate,reliable,efficient and low-consumption,which could be used for the detection of heavy metals in e cigarette aerosols. |
Close |
|
|
|