Simultaneous Determination of 4 Antibiotics in Children’s Cosmetics by Ultra-performance Liquid Chromatography-Tandem Mass Spectrometry with Solid Phase Extraction
  
View Full Text    Download reader
DOI:
KeyWord:antibiotic  children’s cosmetics  ultra-performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS)  purification
  
AuthorInstitution
WANG Yi,NIE Ming-xia,JIA Fang,LIANG Wen-yao,LI Xin-yu,WEN Jia-lin,XIA Ze-min,TAN Jian-hua National Quality Inspection and Testing Center for Cosmetics(Guangzhou),Guangzhou Quality Supervision and Testing Institute,Guangzhou ,China
Hits: 643
Download times: 847
Abstract:
      An ultra-performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS) was established for the determination of 4 antibiotics in children’s cosmetics.The cosmetic samples were extracted with 70% acetonitrile-water solution,and then purified with a SCX column.The target analytes were separated on a Waters ACQUITY BEH C18(2.1 mm × 100 mm,2.5 μm) column using 0.1% formic acid solution and acetonitrile as mobile phases.The analysis was performed under multiple reaction monitoring(MRM) mode.Results showed that there were good linear relationships for 4 antibiotics in the respective concentration ranges with their correlation coefficients(r) of 0.999.The limits of detection(LODs) and limits of quantitation(LOQs) of the method were in the range of 0.005-0.250 μg/g and 0.010-0.500 μg/g,respectively. Average recoveries for the 4 antibiotics in 3 kinds of samples at 3 spiked levels ranged from 89.3% to 113%,with relative standard deviations(RSDs,n = 6) of 0.90%-7.2%.The method is effective,accurate and specific,and it could be used for the determination of 4 antibiotics in children’s cosmetics.
Close