LI Jing,YAN Meng,SHEN Jin-can,XIAO Chen-gui,MAK Yim-ling,LI Yang,GUO Jian-ning,ZHONG Run-sheng 1. Department of Transportation and Environment,Shenzhen Institute of Information Technology,Shenzhen ,China; 2. State Key Laboratory of Marine Pollution(SKLMP),City University of Hong Kong,Hongkong ,China; 3. Key Laboratory of Detection Technology R&D on Food Safety,Food Inspection and Quarantine Technology Center of Shenzhen Customs,Shenzhen ,China
Hits: 593
Download times: 910
Abstract:
      A method was established for the simultaneous detection of 18 marine phycotoxins by ultrahigh performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS) combined with solid phase extraction,including azaspiracids(AZAs),brevetoxins(BTXs),Pacific ciguatoxins(P-CTXs),dinophysistoxins(DTXs),gymnodimine(GYM),maitotoxin3(MTX3),okadaic acid(OA),pectenotoxin2(PTX2),spirolide1(SPX1) and yessotoxins(YTXs) etc.Seawater(1 L) or the ultrasonic extracts of suspended particulate matter or sediment(1 g) was extracted with solid phase extraction cartridges(Agilent Bond Elut C18,500 mg/6 mL),and then 10% glycerol-methanol was added to the eluent to reduce the loss of target toxins.Water was the aqueous phase and 95% acetonitrile/water was the organic phase,both of which contained 0.1% formic acid and 2 mmol/L ammonium formate.A Phenomenex Kinetex C18 column(100 mm × 2.1 mm i.d.,1.7 μm) was used to separate the phycotoxins in six minutes,and then the target analytes were detected by UPLC-MS/MS in multiple reaction monitoring mode.The external standard method was used for the quantitation of 18 phycotoxins.The correlation coefficients of standard curves were 0.991 1-0.999 9.The quantitation limits of the methed for 18 phycotoxins ranged from 0.05 to 250 pg/L(or pg/g).The matrix-spiked recoveries for 18 phycotoxins ranged from 77.4% to 119%,with the relative standard deviations of 1.1%-15%.Ten phycotoxins were detected in seawater from the Pearl River Estuary,with the predominant PTX2 of 36.6-7 900 pg/L.MTX3 concentrations ranging from 0 to 262 pg/L was monitored for the first time.With good sensitivity and precision,this method can satisfy the requirements for simultaneous determination of 18 phycotoxins in seawater,suspended particulate matter and sediment.
Close